If you’ve ever stood in the middle of a sweltering commercial space mid-summer, watching staff and customers dodge warm air while your HVAC system struggles to keep up, you know how critical a chiller unit is to keeping operations running smoothly. As a chiller supplier, I’ve spent the last 12 years helping property managers, architects, and building engineers sort through hundreds of options, and I’ve seen first-hand how a bad chiller choice isn’t just an inconvenience—it’s a hit to your bottom line, your reputation, and even your building’s long-term sustainability goals. Most people don’t realize that choosing a chiller isn’t a one-size-fits-all decision. It’s about matching the unit to your building’s unique needs, the climate you operate in, and your long-term budget. Let’s break this down the way I walk every customer through it, no sales fluff, just real-world, science-backed advice. Chiller Unit

First, you need to start with the basics: calculating your building’s actual cooling load. This isn’t just guessing “how big is the building?” That’s the mistake I see most first-time buyers make. A 50,000-square-foot office in Chicago needs a completely different chiller than the same square footage of a retail space in Phoenix, and neither is the same as a small hotel in Atlanta. Cooling load is the total amount of heat that needs to be removed from the building to maintain a comfortable indoor temperature—usually between 72 and 78 degrees Fahrenheit for commercial spaces, with humidity levels between 40 and 60 percent.
To get this right, you need to account for a long list of variables. First, the building’s occupancy: a 50,000-square-foot office with 200 employees generates more heat from computers, lighting, and people than a small retail space that’s only open 10 hours a day. Then there’s the building’s design: older buildings with single-pane windows and poor insulation will have a higher cooling load than newer constructions with double-pane, low-E glass and spray foam insulation. The orientation of the building matters too—if your west-facing walls get direct afternoon sun, that adds 10 to 15 percent to your load on summer days. You also have to include internal heat sources: server rooms, kitchen exhaust systems, and even lighting can add significant heat, especially in spaces that rely on 24/7 equipment.
I always recommend working with a certified HVAC engineer to do a Manual J calculation (that’s the industry standard for residential and commercial cooling load) instead of relying on generic square footage charts. I’ve had customers come to me saying they needed a 200-ton chiller, only for their engineer to calculate they actually need a 165-ton unit—overbuying doesn’t just cost more upfront, it makes the unit run inefficiently, because chillers work best when operating at 50 to 80 percent of their rated capacity. Run them too small, and you’ll have constant breakdowns and warm indoor air; run them way too big, and you’ll waste energy and wear out parts faster.
Next, you have to choose between the two main types of chillers: air-cooled and water-cooled. This is another decision that trips people up, and it all comes down to your building’s space, local climate, and operational costs. Let’s start with air-cooled chillers. These units use ambient air to dissipate heat, so they don’t need a separate cooling tower or water plumbing system. That makes them easier to install, especially for retrofit projects where you don’t have extra space for a tower or don’t want to modify existing plumbing. They’re also generally quieter than water-cooled units, which is a big plus for buildings that are close to residential areas or have ground-floor chiller rooms.
But air-cooled chillers have a downside: their efficiency drops when the ambient temperature is high. If you’re in a climate where summer temperatures regularly top 95 degrees Fahrenheit, an air-cooled chiller has to work harder to move heat to the air, which means higher energy bills. For example, an air-cooled chiller that has a 10 EER (Energy Efficiency Ratio) at 80 degrees might drop to 8.2 EER at 100 degrees— that’s a 18% drop in efficiency. They also need good airflow around them, so you can’t put them in a tight, enclosed space where air can’t circulate. If your rooftop is already crowded with other HVAC equipment, an air-cooled chiller might not get the airflow it needs to perform.
Water-cooled chillers, on the other hand, use water (usually pumped through a cooling tower) to dissipate heat, so they’re much more efficient in hot climates. Their EER rating is typically 20 to 30 percent higher than a comparable air-cooled unit, which translates to big energy savings over time. They’re also better for large buildings—like hospitals, malls, or high-rises—with cooling loads over 150 tons, because they can handle higher capacities more efficiently. The trade-off is that water-cooled systems need a cooling tower, a water treatment system, and a pump to circulate water, which means more upfront cost, more maintenance, and need for extra space to house the tower. They’re also noisier, and if your local water is hard, you have to add chemicals to prevent scale buildup in the pipes and chiller, which adds to long-term operating costs.
Once you pick the type, you need to look at efficiency ratings, and not just the ones on the product label. The industry uses two main ratings for chillers: EER (Energy Efficiency Ratio) and IPLV (Integrated Part Load Value). EER is the efficiency at full load, which is the maximum cooling capacity, but most chillers don’t run at full load all the time—they run at part load, especially in spring and fall when outdoor temperatures are mild. That’s why IPLV is more important for most commercial buildings. It measures efficiency across different load levels (100%, 75%, 50%, and 25%) and gives a better picture of how the unit will perform over the course of a year. For example, a chiller with a 10 EER might have an IPLV of 12, which means it’s much more efficient when running at part load, where it will spend most of its time.
You also need to consider whether you want a variable-speed or constant-speed chiller. Constant-speed chillers turn on and off as needed, which works well for small, consistent loads, but they waste energy during start-up cycles and when operating at part load. Variable-speed chillers use an inverter to adjust the compressor speed based on cooling demand, so they can run at lower capacities when you don’t need full cooling. This can improve efficiency by 20 to 40 percent, depending on the building’s load profile. The upfront cost is higher, but for most commercial buildings, the energy savings pay for the difference in 3 to 5 years. I recently worked with a 100,000-square-foot office building in Dallas that switched from a constant-speed air-cooled chiller to a variable-speed water-cooled unit, and their annual energy bill for HVAC dropped by $12,000. That’s not a small number for a mid-sized business.
Another big factor is maintenance and serviceability. I’ve seen so many buildings get a great deal on a cheap chiller, only to have it break down 3 years later and find out the parts are hard to get or the supplier doesn’t offer local service. When you’re choosing a chiller, look for units with standard parts that are widely available, and make sure the supplier offers 24/7 service in your area. Ask about the recommended maintenance schedule: a chiller that needs quarterly filter changes and annual compressor checks is easier to service than one that requires specialized tools or a technician from across the country. Also, consider the warranty: most quality chillers come with a 5-year parts warranty, but some offer extended warranties for an extra cost. As a supplier, I always recommend opting for the extended warranty if you plan to keep the building for 10 years or more—it’s a small cost that saves you from expensive repair bills down the line.
Special considerations come into play too, depending on your building’s specific needs. If you’re in a region with strict energy codes or sustainability goals, look for chillers that are ENERGY STAR certified. ENERGY STAR chillers meet strict efficiency standards set by the U.S. Environmental Protection Agency, and they can help you qualify for tax incentives or utility rebates. Many utility companies offer rebates for upgrading to high-efficiency HVAC equipment, which can offset up to 30% of the chiller’s cost. If your building has multiple cooling zones—like a hotel with guest rooms, a restaurant, and a gym—you might want a chiller with multiple compressors, so you can turn off individual compressors when only part of the building needs cooling, which improves efficiency.
If you’re in a climate that gets very cold winters, you need to make sure your chiller can handle low ambient temperatures. Air-cooled chillers can have issues with refrigerant pressure when temperatures drop below 30 degrees Fahrenheit, which can damage the compressor. Many modern units have a heat pump function or crankcase heaters that prevent this, but you need to confirm that the unit is rated for your area’s lowest winter temperature. Water-cooled chillers might need a glycol mix in the pipes if they’re located in areas where temperatures drop below freezing, to prevent the water from expanding and cracking the pipes—something that adds to maintenance and operating costs.
Also, think about your future needs. Are you planning to expand your building in the next 5 to 10 years? If so, you might want to size the chiller slightly larger than your current load, or pick a unit that can be easily expanded with additional modules. Modular chillers are a great option here—they come in multiple small units instead of one large unit, so you can add a module as your needs grow. That’s cheaper and less disruptive than replacing a whole chiller when you expand. For example, a restaurant that starts with a 50-ton modular chiller can add a 25-ton module when they build an outdoor patio or a kitchen expansion, without having to scrap the original unit.
I’ve had customers ask me about buying used chillers, and while it might seem like a way to save money upfront, it’s almost never a good long-term choice. Used chillers are often outdated, less efficient, and might have hidden wear and tear that leads to frequent breakdowns. Also, many used chillers don’t meet current energy codes, so you might not be able to get permits to install them, or you’ll face higher operating costs. The small savings on the purchase price will be eaten up by higher energy bills and repair costs within a few years.
At the end of the day, choosing a chiller is a balance between upfront cost, long-term operating costs, and your building’s unique needs. It’s not about picking the cheapest unit or the most efficient one—it’s picking the right one for your space. If you’re not sure where to start, don’t guess. Talk to a reputable HVAC engineer, and work with a supplier who will take the time to ask about your building’s size, location, occupancy, and long-term goals, not just try to sell you the most expensive unit on the lot.

If you’re ready to stop dealing with inconsistent cooling and high energy bills, and find a chiller that’s built to last for your commercial space, reach out for a no-obligation consultation. We’ll walk through your specific needs, calculate your exact cooling load, and help you find a unit that fits your budget and performance goals, with local support and service whenever you need it.
Screw Chillers References
- Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Chiller Efficiency Standards and Ratings.
- U.S. Environmental Protection Agency. ENERGY STAR Commercial Chiller Guidelines.
- Manual for Commercial Cooling Load Calculations, American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE).
- Department of Energy. High-Efficiency Chiller Selection and Best Practices.